Electrical Network Monitor & Analyzer for Preventive Maintenance.

Electrical Network Monitor & Analyzer for Preventive Maintenance.

 

THE MPR-63 Electrical Network Monitor & Analyzer.

The MPR-63 network analyzer is an electronic instrument which allows the                                 measurement of all your electrical main parameters in the input network in                            real value and RMS value.

It is specially designed for easy installation and programming. It needs three                         voltage signals (RST) and current (I1, I2, I3).

The MPR-63 is supplied with LCD screen backlighted for an easy reading at                           any lighting level. It offers optional communication module and has internal memory.

GENERAL: The MPR-63 is designed for measuring all electrical parameters, including harmonics of an electric network with MODBUS-RTU protocol on RS485 communication port.

 

HARMONIC ANALYZER
MPR-63
 
 
 
GENERAL
MPR-63 is designed for measuring all electrical parameters, including harmonics, of an electric network with MODBUS-RTU protocol on RS-485 communication port
FEATURES
-Total Harmonic Distortion for Voltage (%THD V)
-Total Harmonic Distortion for Current (%THD I)
-Measuring up to 31th Harmonic for current and voltage separately.
-RS-485 Communication.
-Alarm Contact Output.
-Energy Pulse Output or Digital Input (optional).
-4-20mA Analog Output for PLC’s or other auxiliary tracking methods(optional).
-Display Demand Value.
-Display Max/Min Values.
-Parameters and demand values are stored even if supply voltage is OFF.
-Data Logging.
-Real Time Clock.
-Non-flammable enclosure.
-Password for setup
-IEC 61000-6-2, IEC 61000-6-4, IEC 61010-1

Software
MPR-SW: Software for monitoring and saving parameters for multiple use (max. 247 units).




Harmonic Graphic which belongs to the same phase up to 31th harmonic.
 
 


up to
31th
Harmonic
 
Measured Parameters
-Phase-Neutral Voltages (VLN)
-Phase-Phase Voltages (VLL)
-Phase Currents (I)
-Total Current (
å I)
-Power Factor (P.F)
-Cos
j
-Frequency (Hz)
-Active Power (P)
-Reactive Power (Q)
-Apparent Power (S)
-Average Phase-Neutral Voltage
-Average Phase-Phase Voltage
-Total Active Power (
å P)
-Total Reactive Power (
å Q)
-Total Apparent Power (
å S)
-Import Active Energy (kWh)
-Export Active Energy(kWh)
-Reactive Energy-Cap. (kVArh)
-Reactive Energy-Ind. (kVArh)
-Total Harmonic Distortion for Voltage (%THD V)
-Total Harmonic Distortion forCurrent (%THD I)
-Harmonic values for Current and Voltage separately up to 31th 
Harmonic for current and voltage separately.
 

 


MODEL
 
SPECIFICATIONS
 
Electrical Parameters
 

 Operating Voltage

230VAC ±10% ; 50/60Hz
 Network Type
3-phase / 4-wire (Star)
 
3-phase / 3-wire (Delta)
 
3-phase / 3-wire (Aron)
 Accuracy
 

   Voltage & Current

Class 0.5

   Frequency

Class 0.1
   Active Power
Class 1
   Reactive Power
Class 2
 Current Transformer Ratio
1…2 000 (programmable)
 Voltage Transformer Ratio
1,0 … 4000,0 (programmable)
 Measurement input
 

   Voltage

1.0-300.0V AC (L-N), 2.0-500.0V AC (L-L)

   Current

5mA - 5.5A
 Measurement Ranges
 

   Voltage

1.0-400.0 kV

   Current

5 mA - 10 000A

   Frequency

45.0 - 65.0 Hz

   Power

0-200.0 M(W,VAr,VA)

   Energy

999999,9 Wh,VArh
999999,9 kWh,kVArh
9999999 MWh,MVArh
 Power Consumption
<6VA
 Burden
<1VA (Current burden), < 0.5VA (Voltage burden) 
 Demand Time
1-60 min. (programmable)
 Communication Interface
MODBUS RTU (RS 485) - Optically isolated, programmable

   Baud Rate

1200-38400 bps

   Address

1-247

   Parity

no,odd,even
 Alarm Contact
Output 1 / Output 2 : 2 NO Relay; 5A,1250 VA (resistive)
 Energy Pulse Output
Output3: Active Energy pulse output (0,1...30kWh/pulse) NPN Transistor
Output4:ReactiveEnergy pulse output(0,1...30kWh/pulse)NPN Transistor

   Switch Period

Min. 1sec (100...2500 msec pulse width)

   Operation Current

Max. 50mA

   Operation Voltage

5…24VDC, max.30VDC
  Real Time Clock
hh:mm:ss; dd/mm/yy
 Analog Output (optional)
4-20mA
 Display
3.6" LCD with Backlight
 Data Logging
Selectable 28 parameters with Time Stamp (15000 records)
Mechanical Parameters
 
 Equipment Protection
Double Insulation , Measurement Category III
 Ambient OperatingTemp
-5°C, +55°C
 Degree of Protection
IP40 (front panel)
 Connection / Installation
Terminal / Flush-mounting with rear terminals
 Dimensions
96x96mm (PR19)
 Weight / each
0.75kg
 Quantity in 1 package
12 pcs

 